ADM1033
http://onsemi.com
16
The construction of a filter allows the ADM1033 and the
remote temperature sensor to operate in noisy environments.
Figure 29 shows a low-pass R-C-R filter with the following
values: R = 100 W and C = 1 nF. This filtering reduces both
common-mode noise and differential noise.
Figure 29. Filter between Remote Sensor
and ADM1033
100 W
100 W
1 nF
D+
D
REMOTE
TEMPERATURE
SENSOR
Limits, Status Registers, and Interrupts
High and low limits are associated with each measurement
channel on the ADM1033. These can form the basis of system
status monitoring. A status bit can be set for any out-of-limit
condition and detected by polling the device. Alternatively,
SMBusALERT
s can be generated to flag a processor or
microcontroller of an out-of-limit condition.
8-bit Limits
The following is a list of all the 8-bit limits on the
ADM1033:
Table 15. TEMPERATURE LIMIT REGISTERS
Register
Description
Default
0x0B
Local High Limit
0x8B (75癈)
0x0C
Local Low Limit
0x54 (20癈)
0x0D
Local THERM
 Limit
0x95 (85癈)
0x0E
Remote 1 High Limit
0x8B (75癈)
0x0F
Remote 1 Low Limit
0x54 (20癈)
0x10
Remote 1 THERM
 Limit
0x95 (85癈)
Table 16. THERM
 LIMIT REGISTERS
Register
Description
Default
0x19
THERM
 % Limit
0xFF default
Out-of-Limit Comparisons
The ADM1033 measures all parameters in a round-robin
format and sets the appropriate status bit for out-of-limit
conditions. Comparisons are made differently, depending
on whether the measured value is compared to a high or low
limit.
High Limit: ?Comparison Performed
Low Limit: < Comparison Performed
Analog Monitoring Cycle Time
The analog monitoring cycle time begins on powerup, or,
if monitoring has been disabled, by writing a 1 to the monitor/
STBY bit of Configuration Register 1, (Address 0x01). The
ADC measures each one of the analog inputs in turn; as each
measurement is completed, the result is automatically stored
in the appropriate value register. The round-robin monitoring
cycle continues unless it is disabled by writing a 0 to the
monitor/STBY bit (Bit 0) of Configuration Register 1
(Address 0x01).
The ADC performs round-robin conversions and takes
11 ms for the local temperature measurement and 32 ms for
each remote temperature measurement with averaging
enabled.
The total monitoring cycle time for the average
temperatures is therefore nominally.
32 ) 11 + 43 ms
(eq. 2)
Once the conversion time elapses, the round robin starts
again. For more information, refer to the Conversion Rate
Register section.
Fan TACH measurements take place in parallel and are not
synchronized with the temperature measurements in any way.
Status Registers
The results of limit comparisons are stored in the status
registers. A 1 represents an out-of-limit measurement; a 0
represents an in-limit measurement. The status registers are
located at Addresses 0x4F to 0x51.
If the measurement is outside its limits, the corresponding
status register bit is set to 1. It remains set at 1 until the
measurement falls back within its limits and it is read or until
an ARA is completed.
Poll the state of the various measurements by reading the
status registers over the serial bus. If Bit 0 (ALERT
 low) of
Status Register 3 (Address 0x51) is set, this means that the
ALERT
 output has been pulled low by the ADM1033.
Pin 14 can be configured as a SMBusALERT
 output. This
automatically notifies the system supervisor of an
out-of-limit condition. Reading the status register clears the
status bit as long as the error condition is gone.
Status register bits are sticky. Whenever a status bit is set
due to an out-of-limit condition, it remains set even after the
triggering event has gone. The only way to clear the status
bit is to read the status register (after the event has gone).
Interrupt mask registers (Reg. 0x08, Reg. 0x09, Reg. 0x0A)
allow individual interrupt sources to be masked from
causing an ALERT
. However, if one of these masked
interrupt sources goes out of limit, its associated status bit is
set in the status register.
相关PDF资料
ADM1034ARQZ-REEL IC THERM/FAN SPEED CTRLR 16-QSOP
ADN8810ACPZ-REEL7 IC CURRENT SOURCE(12BIT) 24LFCSP
ADP2140ACPZ3328R7 IC REG DL BCK/LINEAR 10LFCSP
ADP5022ACBZ-6-R7 IC REG TRPL BCK/LINEAR 16WLCSP
ADP5041ACPZ-1-R7 IC REG TRPL BCK/LINEAR 20-LFCSP
ADP5042ACPZ-2-R7 IC REG TRPL BCK/LINEAR 20LFCSP
ADT6402SRJZ-RL7 IC TEMP SENS TRIP PT PP SOT-23-6
ADT6501SRJZP085RL7 IC TEMP SENSOR MICROPWR SOT23-5
相关代理商/技术参数
ADM1034 制造商:ONSEMI 制造商全称:ON Semiconductor 功能描述:Thermal Monitor and Fan Speed (RPM) Controller
ADM1034ARQ 制造商:ON Semiconductor 功能描述:Temp Sensor Digital Serial (2-Wire) 16-Pin QSOP Tube 制造商:Rochester Electronics LLC 功能描述:DUAL FAN CONTROLLER, SRC, SMBUS I.C. - Bulk
ADM1034ARQ-REEL 功能描述:IC THERM/FAN SPEED CTRLR 16-QSOP RoHS:否 类别:集成电路 (IC) >> PMIC - 热管理 系列:- 标准包装:1 系列:- 功能:温度监控系统(传感器) 传感器类型:内部和外部 感应温度:-40°C ~ 125°C,外部传感器 精确度:±2.5°C 本地(最大值),±5°C 远程(最大值) 拓扑:ADC,比较器,寄存器库 输出类型:2 线 SMBus? 输出警报:无 输出风扇:无 电源电压:2.7 V ~ 5.5 V 工作温度:-40°C ~ 125°C 安装类型:表面贴装 封装/外壳:SOT-23-8 供应商设备封装:SOT-23-8 包装:Digi-Reel® 其它名称:296-22675-6
ADM1034ARQ-REEL7 功能描述:IC THERM/FAN SPEED CTRLR 16-QSOP RoHS:否 类别:集成电路 (IC) >> PMIC - 热管理 系列:- 标准包装:1 系列:- 功能:温度监控系统(传感器) 传感器类型:内部和外部 感应温度:-40°C ~ 125°C,外部传感器 精确度:±2.5°C 本地(最大值),±5°C 远程(最大值) 拓扑:ADC,比较器,寄存器库 输出类型:2 线 SMBus? 输出警报:无 输出风扇:无 电源电压:2.7 V ~ 5.5 V 工作温度:-40°C ~ 125°C 安装类型:表面贴装 封装/外壳:SOT-23-8 供应商设备封装:SOT-23-8 包装:Digi-Reel® 其它名称:296-22675-6
ADM1034ARQZ 功能描述:IC THERM/FAN SPEED CTRLR 16-QSOP RoHS:是 类别:集成电路 (IC) >> PMIC - 热管理 系列:- 标准包装:1 系列:- 功能:温度监控系统(传感器) 传感器类型:内部和外部 感应温度:-40°C ~ 125°C,外部传感器 精确度:±2.5°C 本地(最大值),±5°C 远程(最大值) 拓扑:ADC,比较器,寄存器库 输出类型:2 线 SMBus? 输出警报:无 输出风扇:无 电源电压:2.7 V ~ 5.5 V 工作温度:-40°C ~ 125°C 安装类型:表面贴装 封装/外壳:SOT-23-8 供应商设备封装:SOT-23-8 包装:Digi-Reel® 其它名称:296-22675-6
ADM1034ARQZ-R7 功能描述:IC THERM/FAN SPEED CTLR 16-QSOP RoHS:是 类别:集成电路 (IC) >> PMIC - 热管理 系列:- 标准包装:1 系列:- 功能:温度监控系统(传感器) 传感器类型:内部和外部 感应温度:-40°C ~ 125°C,外部传感器 精确度:±2.5°C 本地(最大值),±5°C 远程(最大值) 拓扑:ADC,比较器,寄存器库 输出类型:2 线 SMBus? 输出警报:无 输出风扇:无 电源电压:2.7 V ~ 5.5 V 工作温度:-40°C ~ 125°C 安装类型:表面贴装 封装/外壳:SOT-23-8 供应商设备封装:SOT-23-8 包装:Digi-Reel® 其它名称:296-22675-6
ADM1034ARQZ-REEL 功能描述:板上安装温度传感器 2 FAN CTRLR SRC SMBUS IC RoHS:否 制造商:Omron Electronics 输出类型:Digital 配置: 准确性:+/- 1.5 C, +/- 3 C 温度阈值: 数字输出 - 总线接口:2-Wire, I2C, SMBus 电源电压-最大:5.5 V 电源电压-最小:4.5 V 最大工作温度:+ 50 C 最小工作温度:0 C 关闭: 安装风格: 封装 / 箱体: 设备功能:Temperature and Humidity Sensor
ADM1034ARQZ-REEL7 功能描述:IC THERM/FAN SPEED CTRLR 16-QSOP RoHS:是 类别:集成电路 (IC) >> PMIC - 热管理 系列:- 标准包装:1 系列:- 功能:温度监控系统(传感器) 传感器类型:内部和外部 感应温度:-40°C ~ 125°C,外部传感器 精确度:±2.5°C 本地(最大值),±5°C 远程(最大值) 拓扑:ADC,比较器,寄存器库 输出类型:2 线 SMBus? 输出警报:无 输出风扇:无 电源电压:2.7 V ~ 5.5 V 工作温度:-40°C ~ 125°C 安装类型:表面贴装 封装/外壳:SOT-23-8 供应商设备封装:SOT-23-8 包装:Digi-Reel® 其它名称:296-22675-6